Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Med Phys ; 50(10): 5933-5934, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37819174
2.
J Appl Clin Med Phys ; 23(8): e13728, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35861648

RESUMO

PURPOSE: The purpose of this work is to evaluate the Standard Imaging Exradin W2 plastic scintillation detector (W2) for use in the types of fields used for stereotactic radiosurgery. METHODS: Prior to testing the W2 in small fields, the W2 was evaluated in standard large field conditions to ensure good detector performance. These tests included energy dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, and dose rate dependence. Next, scan settings and calibration of the W2 were optimized to ensure high quality data acquisition. Profiles of small fields shaped by cones and multi-leaf collimator (MLCs) were measured using the W2 and IBA RAZOR diode in a scanning water tank. Output factors for cones (4-17.5 mm) and MLC fields (1, 2, 3 cm) were acquired with both detectors. Finally, the dose at isocenter for seven radiosurgery plans was measured with the W2 detector. RESULTS: W2 exhibited acceptable warm-up behavior, short-term reproducibility, axial angular dependence, dose-rate linearity, and dose linearity. The detector exhibits a dependence upon energy, polar angle, and temperature. Scanning measurements taken with the W2 and RAZOR were in good agreement, with full-width half-maximum and penumbra widths agreeing to within 0.1 mm. The output factors measured by the W2 and RAZOR exhibited a maximum difference of 1.8%. For the seven point-dose measurements of radiosurgery plans, the W2 agreed well with our treatment planning system with a maximum deviation of 2.2%. The Cerenkov light ratio calibration method did not significantly impact the measurement of relative profiles, output factors, or point dose measurements. CONCLUSION: The W2 demonstrated dosimetric characteristics that are suitable for radiosurgery field measurements. The detector agreed well with the RAZOR diode for output factors and scanned profiles and showed good agreement with the treatment planning system in measurements of clinical treatment plans.


Assuntos
Plásticos , Radiocirurgia , Calibragem , Humanos , Radiometria/métodos , Radiocirurgia/métodos , Reprodutibilidade dos Testes
3.
Am J Clin Oncol ; 45(5): 202-207, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35446279

RESUMO

OBJECTIVE: The objective of this study was to examine tumor response with positron emission tomography (PET)/magnetic resonance imaging (MRI) during chemoradiotherapy as a predictor of outcome in patients with p16-positive oropharynx cancer. MATERIALS AND METHODS: Patients with p16-positive oropharynx cancer were treated with chemoradiotherapy. Low-risk (LR) disease was defined as T1-T3 and N0-2b and ≤10 pack-years and intermediate-risk (IR) disease as T4 or N2c-3 or >10 pack-years. Patients underwent a PET/MRI scan pretreatment and at fraction 10. Change in value of imaging means were analyzed by analysis of variance. K-means clustering with Euclidean distance functions were used for patient clustering. Silhouette width was used to determine the optimal number of clusters. Linear regression was performed on all radiographic metrics using patient and disease characteristics. RESULTS: Twenty-four patients were enrolled with 7 LR and 11 IR patients available for analysis. Pretreatment imaging characteristics between LR and IR patients were similar. Patients with LR disease exhibited a larger reduction in maximum standardized uptake value (SUV) compared with IR patients (P<0.05). Cluster analysis defined 2 cohorts that exhibited a similar intratreatment response. Cluster 1 contained 7 of 7 LR patients and 8 of 11 IR patients. Cluster 2 contained 3 of 11 IR patients. Cluster 2 exhibited significant differences compared with cluster 1 in the change in primary tumor peak SUV and largest lymph node median SUV. CONCLUSIONS: We identified that IR p16-positive oropharynx cancers exhibit heterogeneity in their PET/MRI response to chemoradiotherapy. These data support further study of intratreatment imaging response as a potential mechanism to identify patients with IR oropharynx cancer suitable for treatment deintensification.


Assuntos
Neoplasias Orofaríngeas , Tomografia por Emissão de Pósitrons , Quimiorradioterapia/métodos , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/terapia , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos
5.
J Appl Clin Med Phys ; 21(8): 309-314, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32648368

RESUMO

Daily output variations of up to ±2% were observed for a protracted time on a Varian TrueBeam® STx; these output variations were hypothesized to be the result of atmospheric communication of the sealed monitor chamber. Daily changes in output relative to baseline, measured with an ionization chamber array (DQA3) and the amorphous silicon flat panel detector (IDU) on the TrueBeam®, were compared with daily temperature-pressure corrections (PTP ) determined from sensors within the DQA3. Output measurements were performed using a Farmer® ionization chamber over a 5-hour period, during which there was controlled variation in the monitor chamber temperature. The root mean square difference between percentage output change from baseline measured with the DQA3 and IDU was 0.50% over all measurements. Over a 7-month retrospective review of daily changes in output and PTP , weak correlation (R2  = 0.30) was observed between output and PTP for the first 5 months; for the final 2 months, daily output changes were linearly correlated with changes in PTP , with a slope of 0.84 (R2  = 0.89). Ionization measurements corrected for ambient temperature and pressure during controlled heating and cooling of the monitor chamber differed from expected values for a sealed monitor chamber by up to 4.6%, but were consistent with expectation for an air-communicating monitor chamber within uncertainty (1.3%, k = 2). Following replacement of the depressurized monitor chamber, there has been no correlation between daily percentage change in output and PTP (R2  = 0.09). The utility of control charts is demonstrated for earlier identification of changes in the sensitivity of a sealed monitor chamber.


Assuntos
Aceleradores de Partículas , Radiometria , Comunicação , Humanos , Estudos Retrospectivos , Incerteza
6.
Med Phys ; 47(8): 3621-3635, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32337734

RESUMO

PURPOSE: The plan-class specific reference field concept could theoretically improve the calibration of radiation detectors in a beam environment much closer to clinical deliveries than existing broad beam dosimetry protocols. Due to a lack of quantitative guidelines and representative data, however, the pcsr field concept has not yet been widely implemented. This work utilizes quantitative plan complexity metrics from modulated clinical treatments in order to investigate the establishment of potential plan classes using two different clustering methodologies. The utility of these potential plan clusters is then further explored by analyzing their relevance to actual dosimetric correction factors. METHODS: Two clinical databases containing several hundred modulated plans originally delivered on two Varian linear accelerators were analyzed using 21 plan complexity metrics. In the first approach, each database's plans were further subdivided into groups based on the anatomic site of treatment and then compared to one another using a series of nonparametric statistical tests. In the second approach, objective clustering algorithms were used to seek potential plan clusters in the multidimensional complexity-metric space. Concurrently, beam- and detector-specific dosimetric corrections for a subset of the modulated clinical plans were determined using Monte Carlo for three different ionization chambers. The distributions of the dosimetric correction factors were compared to the derived plan clusters to see which plan clusters, if any, could help predict the correction factor magnitudes. Ultimately, a simplified volume averaging metric (SVAM) is shown to be much more relevant to the total dosimetric correction factor than the established plan clusters. RESULTS: Plan groups based on the site of treatment did not show noticeable distinction from one another in the context of the metrics investigated. An objective clustering algorithm was able to discriminate volumetric modulated arc therapy (VMAT) plans from step-and-shoot intensity-modulated radiation therapy plans with an accuracy of 90.8%, but no clusters were found to exist at any level more specific than delivery modality. Monte Carlo determined correction factors for the modulated plans ranged from 0.970 to 1.104, 0.983 to 1.027, and 0.986 to 1.009 for the A12, A1SL, and A26 chambers, respectively, and were highly variable even within the treatment modality plan clusters. The magnitudes of these correction factors were explained almost entirely by volume averaging with SVAM demonstrating positive correlation with all Monte Carlo established total correction factors. CONCLUSIONS: Plan complexity metrics do provide some quantitative basis for the investigation of plan clusters, but an objective clustering algorithm demonstrated that quantifiable differences could only be found between VMAT and step-and-shoot beams delivered on the same treatment machine. The inherent variability of the Monte Carlo determined correction factors could not be explained solely by the modality of the treatment but were instead almost entirely dependent upon the volume averaging correction, which itself depends on the detector position within the dose distribution, dose gradients, and other factors. Considering the continued difficulty of determining a relevant plan metric to base plan clusters on, case-by-case corrections may instead obviate the need for the pcsr field concept in the future.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Análise por Conglomerados , Método de Monte Carlo , Aceleradores de Partículas , Radiometria , Dosagem Radioterapêutica
7.
J Appl Clin Med Phys ; 20(12): 25-35, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31675460

RESUMO

Patient dose from 2.5 MV images on the TrueBeam linear accelerator is not easily quantified, primarily because this beam energy is not normally modeled by commercial treatment planning systems. In this work we present the feasibility of using the Eclipse® treatment planning system to model this beam. The Acuros XB and the AAA dose calculation algorithms were tested. Profiles, PDDs, and output factors were measured for the 2.5 MV unflattened imaging beam and used for beam modeling. The algorithms were subsequently verified using MPPG 5.a guidelines. Calculated doses with both algorithms agreed with the measurement data to within the following criteria recommended for conventional therapeutic MV beams: 2% local dose-difference in the high-dose region, 3% global difference in the low-dose region, 3 mm distance to agreement in the penumbra, and a gamma pass rate of >95% for 3%/3 mm criteria. Acuros was able to accurately calculate dose through cork and bone-equivalent heterogeneities. AAA was able to accurately calculate dose through the bone-equivalent heterogeneity but did not pass within the recommended criteria for the cork heterogeneity. For the 2.5 MV imaging beam, both the AAA and Acuros algorithms provide calculated doses that agree with measured results well within the 20% criteria for imaging beams recommended by AAPM TG-180.


Assuntos
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Planejamento de Assistência ao Paciente/normas , Imagens de Fantasmas , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica
8.
J Neurooncol ; 145(2): 385-390, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31606876

RESUMO

PURPOSE: The aim of this study was to determine whether a higher biological effective dose (BED) would result in improved local control in patients treated with fractionated stereotactic radiotherapy (FSRT) for their resected brain metastases. METHODS: Patients with newly diagnosed brain metastases without previous brain radiotherapy were retrospectively reviewed. Patients underwent surgical resection of at least one brain metastasis and were treated with adjuvant FSRT, delivering 25-36 Gy in 5-6 fractions. Outcomes were computed using Kaplan-Meier survival analysis and univariate analysis. RESULTS: Fifty-four patients with 63 post-operative cavities were included. Median follow-up was 16 months (3-60). Median metastasis size at diagnosis was 2.9 cm (0.6-8.1) and median planning target volume was 19.7 cm3 (6.3-68.1). Two-year local control (LC) was 83%. When stratified by dose, 2 years LC rate was 95.1% in those treated with 30-36 Gy in 5-6 fractions (BED10 of 48-57.6 Gy10) versus 59.1% lesions treated with 25 Gy in 5 fractions (BED10 of 37.5 Gy10) (p < 0.001). LC was not associated with resection cavity size. One year overall survival was 68.7%, and was independent of BED10. Symptomatic radiation necrosis occurred in 7.9% of patients and was not associated with dose. CONCLUSION: In the post-operative setting, high-dose FSRT (BED10 > 37.5 Gy10) were associated with a significantly higher rate of LC compared to lower BED regimens. Overall, 25 Gy in 5 fractions is not an adequate dose to control microscopic disease. If selecting a 5-fraction regimen, 30 Gy in five fractions appears to provide excellent tumor bed control.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/terapia , Quimiorradioterapia Adjuvante/métodos , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/patologia , Fracionamento da Dose de Radiação , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
9.
Med Phys ; 46(2): 913-924, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30449040

RESUMO

PURPOSE: The determination of absorbed dose to water from external beam radiotherapy using radiation detectors is currently rooted in calibration protocols that do not account for modulations encountered in patient-specific deliveries. Detector response in composite clinical fields has not been extensively studied due to the time and effort required to determine these corrections on a case-by-case basis. To help bridge this gap in knowledge, corrections for the Exradin A1SL scanning chamber were determined in a large number of composite clinical fields using Monte Carlo methods. The chamber-specific perturbations that contribute the most to the overall correction factor were also determined. METHODS: A total of 131 patient deliveries comprised of 834 beams from a Varian C-arm linear accelerator were converted to EGSnrc Monte Carlo inputs. A validated BEAMnrc 21EX linear accelerator model was used as a particle source throughout the EGSnrc simulations. Composite field dose distributions were compared against a commercial treatment planning system for validation. The simulation geometry consisted of a cylindrically symmetric water-equivalent phantom with the Exradin A1SL scanning chamber embedded inside. Various chamber perturbation factors were investigated in the egs_chamber user code of EGSnrc and were compared to reference field conditions to determine the plan-specific correction factor. RESULTS: The simulation results indicated that the Exradin A1SL scanning chamber is suitable to use as an absolute dosimeter within a high-dose and low-gradient target region in most nonstandard composite fields; however, there are still individual cases that require larger delivery-specific corrections. The volume averaging and replacement perturbations showed the largest impact on the overall plan-specific correction factor for the Exradin A1SL scanning chamber, and both volumetric modulated arc therapy (VMAT) and step-and-shoot beams demonstrated similar correction factor magnitudes among the data investigated. Total correction magnitudes greater than 2% were required by 9.1% of step-and-shoot beams and 14.5% of VMAT beams. When examining full composite plan deliveries as opposed to individual beams, 0.0% of composite step-and-shoot plans and 2.6% of composite VMAT plans required correction magnitudes greater than 2%. CONCLUSIONS: The A1SL scanning chamber was found to be suitable to use for absolute dosimetry in high-dose and low-gradient dose regions of composite IMRT plans but even if a composite dose distribution is large compared to the detector used, a correction-free absorbed dose-to-water measurement is not guaranteed.


Assuntos
Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
10.
J Appl Clin Med Phys ; 19(5): 368-374, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30062720

RESUMO

The management of a pregnant patient in radiation oncology is an infrequent event requiring careful consideration by both the physician and physicist. The aim of this manuscript was to highlight treatment planning techniques and detail measurements of fetal dose for a pregnant patient recently requiring treatment for a brain cancer. A 27-year-old woman was treated during gestational weeks 19-25 for a resected grade 3 astrocytoma to 50.4 Gy in 28 fractions, followed by an additional 9 Gy boost in five fractions. Four potential plans were developed for the patient: a 6 MV 3D-conformal treatment plan with enhanced dynamic wedges, a 6 MV step-and-shoot (SnS) intensity-modulated radiation therapy (IMRT) plan, an unflattened 6 MV SnS IMRT plan, and an Accuray TomoTherapy HDA helical IMRT treatment plan. All treatment plans used strategies to reduce peripheral dose. Fetal dose was estimated for each treatment plan using available literature references, and measurements were made using thermoluminescent dosimeters (TLDs) and an ionization chamber with an anthropomorphic phantom. TLD measurements from a full-course radiation delivery ranged from 1.0 to 1.6 cGy for the 3D-conformal treatment plan, from 1.0 to 1.5 cGy for the 6 MV SnS IMRT plan, from 0.6 to 1.0 cGy for the unflattened 6 MV SnS IMRT plan, and from 1.9 to 2.6 cGy for the TomoTherapy treatment plan. The unflattened 6 MV SnS IMRT treatment plan was selected for treatment for this particular patient, though the fetal doses from all treatment plans were deemed acceptable. The cumulative dose to the patient's unshielded fetus is estimated to be 1.0 cGy at most. The planning technique and distance between the treatment target and fetus both contributed to this relatively low fetal dose. Relevant treatment planning strategies and treatment delivery considerations are discussed to aid radiation oncologists and medical physicists in the management of pregnant patients.


Assuntos
Neoplasias Encefálicas/radioterapia , Adulto , Feminino , Humanos , Imagens de Fantasmas , Gravidez , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Radioterapia de Intensidade Modulada
11.
Cureus ; 10(4): e2422, 2018 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-29872602

RESUMO

Magnetic resonance-guided radiation therapy (MRgRT) offers advantages for image guidance for radiotherapy treatments as compared to conventional computed tomography (CT)-based modalities. The superior soft tissue contrast of magnetic resonance (MR) enables an improved visualization of the gross tumor and adjacent normal tissues in the treatment of abdominal and thoracic malignancies. Online adaptive capabilities, coupled with advanced motion management of real-time tracking of the tumor, directly allow for high-precision inter-/intrafraction localization. The primary aim of this case series is to describe MR-based interventions for localizing targets not well-visualized with conventional image-guided technologies. The abdominal and thoracic sites of the lung, kidney, liver, and gastric targets are described to illustrate the technological advancement of MR-guidance in radiotherapy.

12.
Technol Cancer Res Treat ; 16(3): 366-372, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28168936

RESUMO

PURPOSE: Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. MATERIALS AND METHODS: Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. RESULTS: Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans ( P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% ( P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL ( P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 ( P < .001). Heterogeneity index was comparable between plans, 1.25 versus 1.25 ( P = .98). CONCLUSION: Magnetic resonance imaging-guided tri-cobalt-60 radiation therapy is capable of delivering lung high-quality stereotactic body radiation therapy plans that are clinically acceptable as compared to volumetric-modulated arc therapy-based plans. Real-time magnetic resonance imaging provides the unique capacity to directly observe tumor motion during treatment for purposes of motion management.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Radioisótopos de Cobalto/uso terapêutico , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pulmão/efeitos da radiação , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/normas , Radioterapia de Intensidade Modulada/métodos
13.
Med Phys ; 43(2): 865-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26843247

RESUMO

PURPOSE: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. METHODS: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. RESULTS: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. CONCLUSIONS: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Fluoroscopia , Humanos , Doses de Radiação , Rotação
14.
Radiother Oncol ; 118(2): 416-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26627702

RESUMO

SBRT is increasingly utilized in liver tumor treatment. MRI-guided RT allows for real-time MRI tracking during therapy. Liver tumors are often poorly visualized and most contrast agents are transient. Gadoxetate may allow for sustained tumor visualization. Here, we report on the first use of gadoxetate during real-time MRI-guided SBRT.


Assuntos
Neoplasias Hepáticas/cirurgia , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Avaliação de Medicamentos/métodos , Estudos de Viabilidade , Gadolínio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico , Imagem por Ressonância Magnética Intervencionista/métodos , Pessoa de Meia-Idade
15.
Med Phys ; 42(4): 1739-44, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25832063

RESUMO

PURPOSE: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. METHODS: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derived from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner's HU calibration curve. RESULTS: The ELAC was 0.0516 ± 0.0063 cm(-1) and 0.0580 ± 0.0091 cm(-1) for n-BCA without and with tantalum, respectively, compared to 0.0487 ± 0.0009 cm(-1) for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of -0.29% and -0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum, respectively; dosimetrically appropriate HU values were estimated to be 79 and 199 HU, respectively. CONCLUSIONS: The dosimetric properties of the embolization agents are very close to those of water for a 6 MV beam. Therefore, treating the entire intracranial space as uniform in composition will result in less than 1% dosimetric error for n-BCA emboli smaller than 3.4 cm without added tantalum and n-BCA emboli smaller than 1.1 cm with added tantalum. Furthermore, when effective embolization can be achieved by the neurointerventionalist using n-BCA without tantalum, the dosimetric impact of overriding material properties will be lessened. However, due to the high attenuation of embolization agents with and without added tantalum for diagnostic energies, artifacts may occur that necessitate additional imaging to accurately identify the spatial extent of the region to be treated.


Assuntos
Malformações Arteriovenosas/terapia , Embolização Terapêutica , Embucrilato , Óleo Etiodado , Fármacos Hematológicos , Tantálio/efeitos da radiação , Malformações Arteriovenosas/diagnóstico por imagem , Calibragem , Embolização Terapêutica/métodos , Humanos , Imageamento por Ressonância Magnética , Fótons , Pós , Tomografia Computadorizada por Raios X , Água
16.
Acad Radiol ; 21(4): 523-30, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24594422

RESUMO

RATIONALE AND OBJECTIVES: Pulmonary hypertension (PH) is a complex and fatal disease that is difficult to diagnose noninvasively. This study evaluated previously published computed tomography-based vessel measurement criteria and investigated the predictive power and diagnostic ability of the main pulmonary artery diameter (MPAD) and the ratio of MPAD to aorta diameter (rPA). MATERIALS AND METHODS: The database for this study consisted of 175 PH patients (for whom mean pulmonary artery pressure [mPAP] was known), 16 patients without PH but with known mPAP (non-PH patients), and 114 "normal" patients without known mPAP. The performance of previously published criteria, MPAD > 29 mm and rPA > 1, was determined. The relationship between vessel measurements and mPAP was evaluated through correlation and linear regression analysis. The ability of these measurements to discriminate between patients with and without PH was determined by receiver operating characteristic analysis. RESULTS: For discriminating between PH and "normal" patients, the sensitivity and specificity of the criterion MPAD > 29 mm were 0.89 (0.84-0.93) and 0.83 (0.76-0.90), respectively, and the sensitivity and specificity of the criterion rPA > 1 were 0.89 (0.85-0.94) and 0.82 (0.74-0.89), respectively. At a specificity of 0.95 in the task of separating PH and "normal" patients, the sensitivity of MPAD was 0.81 (0.72-0.90) and the sensitivity of rPA was 0.76 (0.66-0.85), but the specificity for both decreased when non-PH patients were included. For the combined PH and non-PH patient groups, the correlation between the vessel measurements and mPAP was significant but low, and the ability of the vessel measurements to predict mPAP was limited. CONCLUSION: This study found that the sensitivity of previously published vessel criteria for identifying PH patients is high, but the specificity may not be high enough for routine use in a clinical patient population.


Assuntos
Algoritmos , Angiografia/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
17.
Lung Cancer ; 82(2): 190-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24018024

RESUMO

Imaging of malignant pleural mesothelioma (MPM) is essential to the diagnosis, assessment, and monitoring of this disease. The complex morphology and growth pattern of MPM, however, create unique challenges for image acquisition and interpretation. These challenges have captured the attention of investigators around the world, some of whom presented their work at the 2012 International Conference of the International Mesothelioma Interest Group (iMig 2012) in Boston, Massachusetts, USA, September 2012. The measurement of tumor thickness on computed tomography (CT) scans is the current standard of care in the assessment of MPM tumor response to therapy; in this context, variability among observers in the measurement task and in the tumor response classification categories derived from such measurements was reported. Alternate CT-based tumor response criteria, specifically direct measurement of tumor volume change and change in lung volume as a surrogate for tumor response, were presented. Dynamic contrast-enhanced CT has a role in other settings, but investigation into its potential use for imaging mesothelioma tumor perfusion only recently has been initiated. Magnetic resonance imaging (MRI) and positron-emission tomography (PET) are important imaging modalities in MPM and complement the information provided by CT. The pointillism sign in diffusion-weighted MRI was reported as a potential parameter for the classification of pleural lesions as benign or malignant, and PET parameters that measure tumor activity and functional tumor volume were presented as indicators of patient prognosis. Also reported was the use of PET/CT in the management of patients who undergo high-dose radiation therapy. Imaging for MPM impacts everything from initial patient diagnosis to the outcomes of clinical trials; iMig 2012 captured this broad range of imaging applications as investigators exploit technology and implement multidisciplinary approaches toward the benefit of MPM patients.


Assuntos
Diagnóstico por Imagem , Neoplasias Pulmonares/diagnóstico , Mesotelioma/diagnóstico , Neoplasias Pleurais/diagnóstico , Diagnóstico por Imagem/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/terapia , Medidas de Volume Pulmonar , Mesotelioma/mortalidade , Mesotelioma/terapia , Mesotelioma Maligno , Neoplasias Pleurais/mortalidade , Neoplasias Pleurais/terapia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Carga Tumoral
18.
Med Phys ; 40(8): 081916, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927330

RESUMO

PURPOSE: The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alternate response assessment metric, specifically through the study of measurement interobserver variability. METHODS: Two CT scans from each of 31 patients were collected. Using a computer interface, five observers contoured tumor on three selected CT sections from each baseline scan. Four observers also constructed matched follow-up scan tumor contours for the same 31 patients. Area measurements extracted from these contours were compared using a random effects analysis of variance model to assess relative interobserver variability. The sums of section area measurements were also analyzed, since these area sums are more clinically relevant for response assessment. RESULTS: When each observer's measurements were compared with those of the other four observers, strong correlation was observed. The 95% confidence interval for relative interobserver variability of baseline scan summed area measurements was [-71%, +240%], spanning 311%. For the follow-up scan summed area measurements, the 95% confidence interval for relative interobserver variability was [-41%, +70%], spanning 111%. At both baseline and follow-up, the variability among observers was a significant component of the total variability in both per-section and summed area measurements (p<0.0001). CONCLUSIONS: Despite the ability of tumor area measurements to capture tumor burden with greater fidelity than linear tumor thickness measurements, manual area measurements may not be a robust means of response assessment in mesothelioma patients.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Mesotelioma/diagnóstico por imagem , Mesotelioma/terapia , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Mesotelioma Maligno , Pessoa de Meia-Idade , Variações Dependentes do Observador , Resultado do Tratamento
19.
J Thorac Oncol ; 8(4): 478-86, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23486268

RESUMO

INTRODUCTION: The purpose of this study was to investigate the continuous changes in three distinct response assessment methods during treatment as a marker of response for patients with mesothelioma. Linear tumor thickness measurements, disease volume measurements, and lung volume measurements (a physiological correlate of disease volumes) were investigated in this study. METHODS: Serial computed tomography scans were obtained during the course of clinically standard chemotherapy for 61 patients. For each of the 216 computed tomography scans, the aerated lung volumes were segmented using a fully automated method, and the pleural disease volume was segmented using a semiautomated method. Modified Response Evaluation Criteria in Solid Tumors linear-thickness measurements were acquired clinically. Diseased (ipsilateral) lung volumes were normalized by the respective contralateral lung volumes to account for the differences in inspiration between scans for each patient. Relative changes in each metric from baseline were tracked over the course of follow-up imaging. Survival modeling was performed using Cox proportional hazards models with time-varying covariates. RESULTS: Median survival from pretreatment baseline imaging was 12.7 months. A negative correlation was observed between measurements of lung volume and disease volume, and a positive correlation was observed between linear-thickness measurements and disease volume. As continuous numerical parameters, all three response assessment methods were significant imaging biomarkers of patient prognosis in independent survival models. CONCLUSIONS: Analysis of trajectories of linear-thickness measurements, disease volume measurements, and lung volume measurements during chemotherapy for patients with mesothelioma indicates that increasing linear thickness, increasing disease volume, and decreasing lung volume are all significantly and independently associated with poor patient prognosis.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Biomarcadores/análise , Mesotelioma/patologia , Neoplasias Pleurais/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/análise , Feminino , Seguimentos , Humanos , Medidas de Volume Pulmonar , Masculino , Mesotelioma/tratamento farmacológico , Mesotelioma/mortalidade , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Pleurais/tratamento farmacológico , Neoplasias Pleurais/mortalidade , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
20.
J Thorac Oncol ; 7(11): 1728-34, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23059782

RESUMO

INTRODUCTION: Response-assessment metrics play an important role in clinical trials and routine patient management. For patients with malignant pleural mesothelioma (MPM), the standard for response assessment is image-based measurements of tumor thickness made according to the modified RECIST (Response Evaluation Criteria in Solid Tumors) protocol. To classify tumor response, changes in tumor thickness are compared with the standard RECIST -30% and +20% cutoffs for partial response (PR) and progressive disease (PD), respectively, which are not specific to MPM. The purpose of this work is to optimize the correlation between tumor response and patient survival by assessing the validity of existing response criteria in MPM and proposing alternative criteria. METHODS: Computed tomography measurements of tumor thickness were acquired at baseline and throughout treatment for 78 patients undergoing standard-of-care chemotherapy. Overall survival was correlated with best response and first follow-up response using Harrell's C statistic. The response criteria for PD and PR were each varied in 1% increments to obtain optimized classification criteria. The performance was cross-validated using a leave-one-out approach. RESULTS: Median survival was 14.9 months. The performance of the standard RECIST criteria in correlating response with survival was C=0.778, whereas the optimized performance of C=0.855 was obtained with criteria of -64% for PR and +50% for PD. After cross-validation, this performance was slightly reduced to C=0.829. CONCLUSIONS: Optimized tumor-response classification criteria were obtained for patients with MPM. These criteria improve the correlation between image-based response and patient survival.


Assuntos
Antineoplásicos/normas , Mesotelioma/classificação , Neoplasias Pleurais/classificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/uso terapêutico , Feminino , Seguimentos , Humanos , Masculino , Mesotelioma/tratamento farmacológico , Mesotelioma/mortalidade , Mesotelioma/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Pleurais/tratamento farmacológico , Neoplasias Pleurais/mortalidade , Neoplasias Pleurais/patologia , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...